Innergy Ondol

The floor is the heater.

Innergy Bars lie under your floor in insulated blocks. A heat pipe in each bar carries warmth from a small heater along its whole length, and stone around it holds that warmth and gives it back slowly. No boiler, no water pipes, no hot air.

01Layout

Planned from your floor plan, room by room.

Each room is filled with 900 mm insulating blocks. Two 1650 mm bars sit in each pair of blocks, and one thermostat runs two zones. You get a count for every room before anything is installed.

Living Bedroom Room
02The bar

A heat pipe in stone, in aluminium.

A 150 W PTC heater clamps onto the copper end of a sealed heat pipe. The water inside boils and condenses, carrying heat to the far end in seconds. Elvan stone packed around the pipe stores it, and the aluminium case spreads it into the floor.

Aluminium case Elvan stone Heat pipe PTC heater 150 W
03The floor

About 73 mm from slab to plywood.

Insulating block, bar, steel diffusion plate and plywood lay dry over a level slab, then your finished floor goes on top. No screed to pour and wait for.

Finished floor Plywood 12 mm Steel plate 0.6 mm Innergy Bars EPP block 60 mm Level slab
04Control

Two zones per thermostat, on the wall.

Each thermostat runs two zones, each with its own floor sensor. Set it on the wall and it keeps working with no app, no account and no internet. The thermostat holds the temperature ceiling itself.

ZONE 1 · ZONE 2 24° 22° Zone 1 Zone 2
Inside the floor

It's what's under the floor that counts.

Six parts, made to be laid dry and wired by an electrician.

Bar1650mmAluminium case, 70 × 44 mm, heat pipe in elvan stone
Heater150WPTC heater on each bar's copper end
Block900mmInsulating EPP block, 60 mm thick, grooved for the bars
Stack73mmSlab to plywood top, before your finished floor
Plate0.6mmSteel diffusion plate over each block
Zones2per thermostatEach with its own floor sensor; works with no app
Heat pipe

Heat moves as vapour.

Inside the sealed copper pipe, a little water boils at the heated end and condenses at the far end. That carries heat many times faster than solid copper, so the whole bar warms almost at once instead of from one end.

Elvan stone

Stone keeps it.

Elvan stone packed around the pipe soaks up the heat and releases it slowly, so the floor stays warm between heater cycles. It is the same idea as a traditional ondol floor, made thin.

In 3D

Turn it over in your hands.

It starts with less than a cup of boiling water: dip the heat pipe and watch the heat run to the far end in seconds. Then drag to turn, scroll or pinch to zoom. Lay the bars into a home, open up an Innergy Bar, dock a canister on the Solar Shower Kit, or run the kit's app.

The model loads when you reach it.

The floor layout is an example home; your quote is drawn from your own plan.

App build · Solar Shower Kit

Sensors join when they plug in.

The kit's firmware is written in Rust. Every sensor is a type that implements one trait, so the controller works with whatever is attached. When a canister docks, the dock reads its ID chip and that canister's tank sensor and float join the bus. The app shows what the unit reports; the unit makes every decision.

// Hundredths of a degree: 4900 = 49.00 °C (120 °F). Integers, no floats.
pub struct CentiC(pub i16);
pub const CAP: CentiC = CentiC(4900);

pub trait TempSensor { fn read(&mut self) -> Result<CentiC, SensorFault>; }
pub trait Dock {
    // None: nothing docked, or a canister with no ID. The pump stays off.
    fn present(&mut self) -> Option<CanisterInfo>;
    fn pull_started(&mut self) -> bool;
}

impl<S: TempSensor, O: Output, G: EventLog> Controller<S, O, G> {
    pub fn request(&mut self, requested: CentiC) {
        // Over the cap is refused and recorded, never rounded down.
        if requested > CAP { self.log.append(&Event::Refused { requested, limit: CAP }); return; }
        self.target = requested;
    }
    pub fn tick(&mut self) {
        match self.tank.read() {
            Ok(t)  => self.element.set(t < self.target && t < CAP),
            Err(f) => { self.element.set(false); self.log.append(&Event::Fault(f)); }
        }
    }
}

On the bus now

what the unit reports to the app
Collector sensor T1JOINED
Canister A · ID chip, 30 LJOINED
Canister A · tank sensor T2 + floatJOINED
Clip-on shower unit · outlet T3JOINED
Canister with no ID chipREFUSED · PUMP OFF
The unit decides.Ask for 130 °F from a modified app and the unit refuses and records it. The cap lives in the firmware, not the app.
A fault turns the heat off.An open or shorted sensor reads as an error, not a temperature. The element switches off and the reason shows in the app.
Tested in the build.Every firmware build runs the tests: 121 °F is refused, an open sensor stops the heat, the element runs only below target.
Request a quote

See what your floor needs.

Tell us the rooms and their sizes. You get a count of blocks, bars and thermostats for each room and a price before anything is ordered.

Innergy Ondol is installed in Korea today. US installations wait on a US safety listing for the bar; we'll tell you plainly where that stands.